Pulse Group Suppression EMI Filters

Payment Type: T/T
Incoterm: FOB,CFR,CIF,EXW
Min. Order: 2 Piece/Pieces
Delivery Time: 7 Days

Basic Info

Model No.: FTES1

Operating Frequency: 50/60Hz

Climatic Category(IEC 60068-1): 25/085/21(-25℃ /+85℃ Damp Heat Test For 21 Days)

Rated Voltage: 110/250VAC

Rated Current: 1-10A@40℃

Test Voltage: 1500VDC, 3S(line-line); 1500VAC, 3S(line-ground)

Additional Info

Packaging: Carton

Productivity: 500,000pcs annually

Brand: FILTEMC

Transportation: Ocean,Air

Place of Origin: Jinan

Certificate: ISO9001, CE, UL, TUV, RoHS

HS Code: 8548900001

Port: Qingdao,Tianjin,Beijing

Product Description

Pulse group series EMI filters are specially designed to suppress fast and transient pulse group interference based on the principle that absorption and reflection are complementary to each other. Benefit from advanced designed method and many years practical experience in EMC field, FTES1 series filters provided by FILTEMC have excellent attenuation effect of fast and transient pulse group interference.
Specially designed to meet customers electric fast and transient pulse group test of L, N, G lines.Depending on different applications there are different requirement regarding electric fast and transient pulse group test ( variable from 1KV to 4KV), so there is no standard product for this series, but only customized according to specific requirement.
Very short lead time for product design, able to meet customer`s urgent requirement of passing pulse group test.

Suitable for all kinds of household appliances, watt-hour meter, alarm equipment, electric testing equipment, fuel dispenser and other civilian or military measuring or controlling device compliance with IEC-61000-4-4 or GB/T17626.4-1998 Standard.


EMI Filter certificates CE RoHS UL


EMI Filter

1. Storage of Surge Suppression Filters: 

  •  The Powerline EMI Filter mustn't be left out in the heat of the sun or exposed to the rain, it should be stored in warehouse with good ventilation, surrounding temperature between -30℃ and +65℃ , the highest relative air humidity lower than 90%, and no corrosive liquid or gas.

2. Installation of Powerline EMI Filter:  

  • Powerline EMI Filter should be installed at power input, and the line inside the chassis be as short as possible to reduce radiated interference. 
  • Both input and output lines of Inverter filters neither be intersected nor be tied up by string.
  • Make sure the mounting flange fully grounded, and keep the ground cable as short as possible if filters are connected to other equipment. 
  • If the terminal is stud, please use two spanners to fasten the screw nut when connecting to avoid stud rotating and thus causing changes to the internal circuit and consequently leading to filters arcing, short circuit, broken down or the filtering effect worsened. 
  • First use spanner1 to fix the screw nut near the metal case, then use spanner2 to tighten the screw nut in front( shown as Figure1), otherwise the terminals may be damaged. 
  • Apply the same for the connection of other phases.


Requests for samples of any catalog item are available for engineering evaluation Free of Charge.

All EMI Filters are RoHS compliant and approvals held include CE, UL,cUL and TUV.

All quality control procedures are fully documented and available for review. FILTEMC is ISO 9001 compliant.