DC Single Phase 2-Stage Power Line EMI Filter

Payment Type: T/T
Incoterm: FOB,CFR,CIF,EXW
Min. Order: 2 Piece/Pieces
Delivery Time: 7 Days

Basic Info

Model No.: FT121D

Operating Frequency: 50/60Hz

Climatic Category(IEC 60068-1): 25/085/21(-25℃ /+85℃ Damp Heat Test For 21 Days)

Rated Voltage: 110/250VAC

Rated Current: 1-10A@40℃

Test Voltage: 1500VDC, 3S(line-line); 1500VAC, 3S(line-ground)

Additional Info

Packaging: Carton

Productivity: 500,000pcs annually

Brand: FILTEMC

Transportation: Ocean,Air

Place of Origin: Jinan

Certificate: ISO9001, CE, UL, TUV, RoHS

HS Code: 8548900001

Port: Qingdao,Tianjin,Beijing

Product Description

Introduction of DC Single Phase 2-Stage Power Line EMI Filter:

Rated current: 0.5~2000A
Working voltage: 0~250VDC
Various terminals: wire, solder lug, stud
Custom specific versions on request

Features and Benefits of Single Phase EMI Filter:

  • High performance DC Electrical Filters with exceptional common and differential mode filtering effect
  • for interference from 10KHz to 30MHz.
  • FT1200D series are two-stage filters comprising one common mode and one differential
  • mode with enhanced filtering effect of the differential mode interference.
  • FT121D series are two-stage common mode filters
  • High voltage versions above 250VDC are also available upon request


Typical Applications of RFI Power Line Filter:


Suitable for switch power supply, SPC exchange and other DC electric device


EMI Filter certificates CE RoHS UL


Electrical Filters

1. Storage of Single Phase EMI Filter: 

  •  The Electrical Filters mustn't be left out in the heat of the sun or exposed to the rain, it should be stored in warehouse with good ventilation, surrounding temperature between -30℃ and +65℃ , the highest relative air humidity lower than 90%, and no corrosive liquid or gas.

2. Installation of Electrical Filters:  

  • Single Phase EMI Filter should be installed at power input, and the line inside the chassis be as short as possible to reduce radiated interference. 
  • Both input and output lines of Inverter filters neither be intersected nor be tied up by string.
  • Make sure the mounting flange fully grounded, and keep the ground cable as short as possible if filters are connected to other equipment. 
  • If the terminal is stud, please use two spanners to fasten the screw nut when connecting to avoid stud rotating and thus causing changes to the internal circuit and consequently leading to filters arcing, short circuit, broken down or the filtering effect worsened. 
  • First use spanner1 to fix the screw nut near the metal case, then use spanner2 to tighten the screw nut in front( shown as Figure1), otherwise the terminals may be damaged. 
  • Apply the same for the connection of other phases.


Requests for samples of any catalog item are available for engineering evaluation Free of Charge.

All EMI Filters are RoHS compliant and approvals held include CE, UL,cUL and TUV.

All quality control procedures are fully documented and available for review. FILTEMC is ISO 9001 compliant.



Contact Person: Cindy Suen

Phone:+86-531-58622885

Fax:+86-531-58622899

Address: Building 20, Xinmao Qilu Science and Technology City, No. 1 Zidong Road,Tianqiao District,,Jinan,Shandong

quick navigation

Sweep wechat

Sweep surprise

Phone:+86-531-58622885

Contact Us Now